RELEASE: WatchMon toolkit 1.0.16 - firmware 1.28

Download the setup via WatchMonToolkitInstaller_1.0.16.msi.

New Features

  • Brusa NLGxx charger, enable integration with Brusa charging equipment.
  • Bypass Tester tool, included for use when commissioning installation.
  • CellMon Led tool, included for troubleshooting to identify CellMon in network chain.

Enhancements

  • Lifetime counters and timestamp when switching to limited power LIMP for Charging / Discharging.
  • Software Installer improved to have minimal dialog steps and include Batrium Logo.
  • Split Control Overview to VoltView and TempView.
  • Sound added to activities on start, stop and error.
  • Simplify technician screen for Shunt Metric Soc% / Cycle changes

Fixes

  • Solax inverter transmission is slowed for hybrid inverter to allow operation.
  • Shunt capacity is calculated correctly for reverse orientation
  • Shunt SoC% capacity accumulator handle repeated fast restarts. 
  • Ensure if multiple systems on network only update with connected system.