Wiring a Circuit Breaker to Onboard WatchMon supervisor

Common Positive Sense Schneider Electric Circuit Breaker - On-board control WatchMon4

How to connect the WatchMon4 to the Schneider Electric Circuit Breaker

When connecting to the controlled  Outputs (that are using mosfet's) make sure that these loads  do not have large inrush currents.  Watchmon supervisor and expansion boards outputs are rated to 3A (default), they will fail when the inrush currents exceed their rating (x2 even for micro/milliseconds).

For large (or unknown) loads make sure you use a external relay/SSR (solid state relays) that is appropriate for the rated purpose.

Generic Circuit Breaker (No Sense) - On-board Control WatchMon4

Generic Common Negative Sense Circuit Breaker - On-board control WatchMon4

Locating Input & Output Connections on WatchMon4